steam boiler id fan impeller

Industrial boilers

Product thermal capacity: 4-35 t/h

Working pressure: 1.0-2.5 MPA

Outlet temperature: 184-350 ℃

Available fuel: natural gas, coke oven gas, bio-gas,liquid propane gas, diesel, heavy oil, light oil, crude oil

Available industries: Petroleum, chemical, chemical fiber, pharmaceutical, textile printing and dyeing, building materials, wood processing, vegetable oil processing and other industries

  • Product introduction
  • Technical advantages
Introduction

steam boiler id fan impeller have a three-pass round coil structure. A conical coil is used for the effective protection of the furnace wall at the boiler end. This product is equipped with an advanced combustion device and is fully automated in operation. After the burner ignites the fuel, flame fills the round coil tubes and transfers heat by radiation through the tube wall (first pass). The high temperature flue gas gathers at the back door and then turns to the convection tubes section (second pass), where heat transfer takes place by convection. The flue gas gradually cools down here and flows to the front door, where it is reversed and goes into the third pass. After that, it enters into the chimney through the economizer and is released into the atmosphere.


steam boiler id fan impeller.This type of heater is delivered as a whole, and is installed on site, it only needs to connect thermal gas(oil) piping and electricity to start operation. The heater has four heating areas: furnace radiation heating area, the first convection tube bundle heating area, the second convection tube bundle heating area and economizer (waste heat boiler).

Digitized manufacture
  • The laying-off of steel tube adopts CNC 3D laser cutting machine.
  • The manufacture of round coil tube adopts CNC coil tube automatic production line. Once-forming and no need for plastic .
Full argon arc welding
  • The tube butt adopts argon arc welding technique and the seams will be done x ray real-time imaging, preventing unqualified seams from entering coil production line .
Easy operation
  • Heater is wholly assembled before delivery, it is easy for installation, debugging and operating.
  • Fully automatic operating, burning, liquid level of high level tank, outlet temperature and flow rate are adjusted automatically and self-protected.
  • The inlet and outlet with end flanges and flanged cover structure facilitate the installation and layout of tubeline in boiler house.
Less fuel consumption
  • Internal side adopts good insulation material, outside uses stainless steel plate, which can mostly reduce heat lost and make working environment better.
  • Multilayers closely spaced tube bundle and steel rod is used to seal and fix, completely eradicating short circuit of flue gas.
  • Before delivery, the residue moisture is removed completely, so the system draining period is reduced to 2 days from 12 days.
Safely operation
  • The inner coil tube has bigger flow rate, so it is more stable under high temperature operation.
  • Conical coil effectively protects the furnace wall at the end of heater and burner on the top.
steam boiler id fan impeller steam boiler id fan impeller steam boiler id fan impeller

9_Single Pass Bagasse_Coal Fired for Power Generation[

2011-3-6 · The design criteria for the project required a 45 bar Water tube Boiler capable of generating 100 t/h of steam firing bagasse or 80 t/h steam on coal

lexie@zozen.com > Get A Quote >

how to calculate a id fan capacity and sutable motor

how to calculate a id fan capacity and sutable motor in kw's.i have a fan impeller dia is 1050mm, width is 105mm in impeller inside to inside,and impeller section cone gap is 450mm, impeller plate thick is 5mm,what is the sutable motor and how cen i calculate the fan …

lexie@zozen.com > Get A Quote >

Boiler SA Fan - Boiler SA Fan Exporter, Manufacture

We are dedicatedly engaged in offering a qualitative range of Boiler SA Fan. These SA fans are acknowledged for their high quality and durability, among our customers across the nation. The offered SA fans can be customized, as per requests of our customers, nationwide.

lexie@zozen.com > Get A Quote >

coil type – ibr small industrial steam boiler, hig

2018-6-7 · We offer a wide range of Boiler ID fan, FD fan & PA fan those are available in different dimensions and specifications. We make you feel the difference of best quality induced draft fan with us. I.D. Fan Impeller: We offer an extensive range of ID Fan Impeller to our customers. Our range is available in various types which covers a huge

lexie@zozen.com > Get A Quote >

LESSONS LEARNT FROM TROUBLESHOOTING - venus

2013-9-26 · The ID fan impeller change / Fan change did not help. • Diagnosis: The ducting system sizing was reviewed. The high pressure drop causing locations were identified and rectified. Even the chimney inlet opening in the concrete chimney was • Problem: The bi drum boiler is a saturated steam boiler without economizer. The pressure of the

lexie@zozen.com > Get A Quote >

id fan centrifugal fan industrial boiler -

Industrial Fan - ID Fan Manufacturer from Mumbai. Laxmi Udyog designs and manufactures a large range of Industrial ID Fan and heavy duty fans. The centrifugal fans can be supplied in single or double stages model, providing an installed power up to 500 kW and attaining air flows of 500000 m 3 /h.

lexie@zozen.com > Get A Quote >

Products-Large Air Capacity FanIndustrial centrifugal

SIMO is one of the largest industrial centrifugal fan manufacturer in central of China, which was found in 1955. It mainly produce centrifugal fan, axial fan application in power plant, cement mill, metallurgy, dust collector, FD fan and so on. 60 years of hardship, hundred of persons bitterly toil, SIMO has become a well known brand, today.

lexie@zozen.com > Get A Quote >

Boiler Id Fan, Boiler Id Fan Suppliers and

Alibaba.com offers 165 boiler id fan products. About 61% of these are centrifugal fans, 27% are axial flow fans, and 3% are boiler parts. A wide variety of boiler id fan …

lexie@zozen.com > Get A Quote >

Malaysian oil fired boilers prices - zorginharen.

how to calculate a id fan capacity and sutable motor . how to calculate a id fan capacity and sutable motor in kw's.i have a fan impeller dia is 1050mm, width is 105mm in impeller inside to inside,and impeller section cone gap is 450mm, impeller plate thick is 5mm,what is the sutable motor and how cen i calculate the fan . Get A Quote

lexie@zozen.com > Get A Quote >

Fan Impeller Manufacturers, Suppliers & Exporters in

Deals in Steam Separator, Turbine, Railing, Super Heater Tube, boiler feed pump, Boiler Furnace Tube, Grating, Deareator Tank, steam piping, Boiler FD Fan, Gas Trainch, Fan Impeller, Boiler id fan, dumping grate boiler, Gear Box with Alternator, Fire grate, Common Steam Header

lexie@zozen.com > Get A Quote >

how to calculate a id fan capacity and sutable motor

how to calculate a id fan capacity and sutable motor in kw's.i have a fan impeller dia is 1050mm, width is 105mm in impeller inside to inside,and impeller section cone gap is 450mm, impeller plate thick is 5mm,what is the sutable motor and how cen i calculate the fan …

lexie@zozen.com > Get A Quote >